Corrected Platelet Count Increment
To evaluate the effectiveness of platelet
transfusion
Purpose:
Pre-transfusion platelet count performed
Post-transfusion platelet count performed in 1 hour
Calculation:
CCI =
post count – pre count
x
body surface area (m
2
)
# platelets/unit x 10
11
Normal CCI:
7500 x 10
11
/m
2